Fieldbus Terminal Controller

BC3150 | PROFIBUS-DP "Compact" Bus Terminal Controller
Bus Terminal Controller with PLC functions are bus coupler.Controller there is a PROFIBUS-DP Fieldbus interface, can be PROFI-BUS system as a smart use from the station.
"Compact" BC3150 Bus Terminal Controller and relatively small economy.And BC3100 are different, BC3150 through the K-bus extension technology, can connect up to 255 bus terminal.Both PROFIBUS controller can automatically detect the baud rate, the largest up to 12 Mbaud, the use of two address selection switches distribution address.
BX series Bus Terminal Controllers larger memory, and there is an additional interface for connecting other I / O devices.
Bus terminal controller to use in line with the IEC 61131-3 standard programming TwinCAT.BC31xx configuration and PLC programming interface used to load program.If you use the software PLC Twin-CAT, while the PLC program can also be loaded through the fieldbus.Bus terminal is connected to the input / output in the PLC's default setting has been assigned.Each Bus Terminal can be configured so that it directly through the implementation of fieldbus control unit and the upper data exchange.Similarly, the data pre-processing can also be achieve through the Fieldbus bus terminal controller and the upper data exchange between controllers.
Distributed signal processing for the PLC
BC3150 use in line with the IEC 61131-3 standard TwinCAT program can be independent of the equipment manufacturers.PLC programs can use five different programming languages (IL, FBD, LD, SFC, ST) preparation.In addition, TwinCAT provided a lot of debugging functions (such as breakpoints, single step, monitoring, etc.) to make debugging easier.It can also scan to the cycle of conditioning and testing was conducted.
| PLC Parameters | PROFIBUS | BC3150 |
| Programmatically | TwinCAT (through the programming interface or fieldbus) |
| Program memory | 48 kbyte |
| Data memory | 32 kbyte |
| In the data | 2 kbyte |
| Operation System | 1 PLC task |
| PLC cycle of inter - | 1000 instructions about 3 ms (K Bus, I / O cycle between being disregarded) |
| Programming language | IEC 61131-3 (IL, LD, FBD, SFC, ST) |
| Online change | Have |
| Technical parameters | BC3150 |
| The number of bus terminals | 64 (if the use of K-bus extension technology, to 255) |
| Fieldbus largest number of bytes | 128 bytes input and 128 bytes output |
| Process image of the largest number of bytes | 512 bytes input and 512 bytes output |
| Digital I / O signal | 2040 Input / Output |
| Analog I / O signal | 128 input / output |
| Parameter setting | KS2000 or through fieldbus |
| Baud rate | Automatically detects the maximum speed up to 12 Mbaud |
| Bus Connection | 1 D-sub 9-pin interface |
| Power Supply | 24 V DC (-15% / +20%) |
| Input current | 320 mA maximum |
| Startup Current | 2.5 times the continuous current |
| k-bus power supply maximum current | 1000 mA |
| Power contact voltage | The largest 24 V DC |
| Power contact load current | Maximum 10 A |
| Electrical isolation | 500 V rms(power contact / supply voltage) |
| Weight | 100 g |
| Operating temperature | 0 ° C ... +55 ° C |
| Storage Temperature | -25 ° C ... +85 ° C |
| Relative Humidity | 95%, non-condensing |
| Anti-vibration / shock resistance | Comply with EN 60068-2-6/EN 60068-2-27/29 |
| And instantaneous pulse electromagnetic interference / electrostatic discharge | In line with EN 61000-6-2 (EN 50082) / EN 61000-6-4 (EN 50081) |
| Protection Level / installation location | IP 20 / variable |