Tsinghua Sunshine building gas-solid heat exchange testing program
Energy-saving emission reduction test-bed gas-solid heat exchange - Data Acquisition System
System Description:
Tsinghua University, for a gas-solid heat exchange building environmental testing, with data acquisition system (SCADA), after a communication system is divided into 3 parts:
- Sensor will send parts: sensor will send, and performance specifications to meet the requirements, through the signal cable connection cabinet collection.
- Acquisition counter parts: the analog signal to analog-to-digital conversion, providing an interface for collecting part of the calculation shows.
- Some calculations show: Run the configuration software, the completion of bus data collection, storage and display.

Data acquisition module can be used SCADA, data logging devices, industrial control cards, each with its own characteristics: SCADA module flexible, scalable, and rich interfaces to meet the needs of a variety of performance; simple data logging devices, the appearance of a fixed shell, if the performance differences, must be ordered; Industrial card collection for the centralized control IPC, board in one part of the calculation and collection of parts shows that combined the need for greater control cabinet. Comprehensive analysis, the use of SCADA modules to better meet the system requirements. Therefore, the data acquisition program, using Advantech 4000 Series module to collect sensor signals and, through the acquisition cabinet package, SCADA modules, complete analog-to-digital conversion, and 485 for the computer platform for data collection, storage and display .
Basic requirements:
Serial number | Name | Specifications | Amount | Remarks |
1 | Temperature measurement using thermocouples | K-type, an accuracy (deviation of temperature measurement to allow ± 3 ℃). Length 400mm, Φ1, sheathed, wire-type compensation (3m compensation wires), temperature range 100 ~ 1000 ℃. | 30 | Temperature measurement of materials used, not damaged in the transfer process. |
2, | Experimental wall temperature measured with thermocouple paragraph | K-type, an accuracy (deviation of temperature measurement to allow ± 2 ℃). Length 100mm, Φ1, sheathed, fixed card pack thread. Temperature range of 0 ~ 800 ℃. 3m wire compensation. | 18 | Wall temperature measured by the test segment. |
3 | Import and export of air temperature measurement using thermocouples | K type, temperature deviation allowed ± 2 ℃. Length 220mm, Φ3, sheathed, fixed card pack thread. Temperature range of 0 ~ 800 ℃. 3m wire compensation. | 4, | Air temperature measured by the import and export. |
4, | Vortex Flowmeter | Flow range of 50 ~ 480m3 / h, working temperature lower than 250 ℃, working pressure range 2kpa ~ 25kpa. | 1 | Measuring air flow, and less than 0.5% error of the requirements, taking into account the conditions at the scene pipeline, the need for tube with steady flow. Two-wire system. Live show, 4 ~ 20mA output (please specify the need for power supply). |
5, | Adjustable range pressure transmitter | Absolute pressure of 0 ~ 200kPa, accuracy 0.2%. | 1 | Live show, 4 ~ 20mA output. |
Six | Intelligent Adjustable Differential Pressure Transmitter | 0 ~ 15kPa, accuracy 0.2%. | 1 | Live show, 4 ~ 20mA output |
7 | Data Acquisition | In 0.2 seconds to complete its one-channel data acquisition overall. Requirements of the relevant software package. 16-bit resolution, or 12-bit resolution. Please quote separately. | 1 | Signal Acquisition Description: two experimental programs: 1) 52 K-type thermocouple signal, three signal 4 ~ 20mA; 2) 10 S-type thermocouple (temperature measurement of materials used), 22 K-type thermoelectric dual, 3 4 ~ 20mA signal. |
8, | Data acquisition software and development | Acquisition software around 128 points, the data can be exported Excel spreadsheet. | 1 | According to our request for a certain degree of data processing, software development accordingly. |
Product Description:
1, sensing transmission parts
1 | Temperature measurement using thermocouples | K-type, an accuracy (deviation of temperature measurement to allow ± 3 ℃). Length 400mm, Φ1, sheathed, wire-type compensation (3m compensation wires), temperature range 100 ~ 1000 ℃. | Kunlun Coast | Support | 30 |
2 | Experimental wall temperature measured with thermocouple paragraph | K-type, an accuracy (deviation of temperature measurement to allow ± 2 ℃). Length 100mm, Φ1, sheathed, fixed card pack thread. Temperature range of 0 ~ 800 ℃. 3m wire compensation. | Kunlun Coast | Support | 18 |
3 | Import and export of air temperature measurement using thermocouples | K type, temperature deviation allowed ± 2 ℃. Length 220mm, Φ3, sheathed, fixed card pack thread. Temperature range of 0 ~ 800 ℃. 3m wire compensation. | Kunlun Coast | Support | 4 |
4 | Vortex Flowmeter | Flow range of 50 ~ 480m3 / h, working temperature lower than 250 ℃, working pressure range 2kpa ~ 25kpa. | Kunlun Coast | Sets | 1 |
5 | Adjustable range pressure transmitter | Absolute pressure of 0 ~ 200kPa, accuracy 0.2%. | Kunlun Coast | Sets | 1 |
6 | Intelligent Adjustable Differential Pressure Transmitter | 0 ~ 15kPa, accuracy 0.2%. | Kunlun Coast | Sets | 1 |
2, collected in part
ADAM-4118

- 8 independent channel differential configuration
- Wide Temperature Operation
- Wider operating temperature: -40 - +85 ° C
- High noise immunity: 1kV voltage input surge protection, 3KV EFT and 8KV ESD protection
- Strong anti-interference: 1KV input power surge protection, 3KV EFT, 8KV ESD protection
- Wide power input range: +10 ~ +48 VDC
- Input range: +10 ~ +48 VDC
- Easy to monitor the state of the LED indicator light
- To support the filtering parameters automatically adjust 50HZ/60HZ
- Support for auto-tuning or filter the output filter 50Hz/60Hz
- Instructions to increase LED Address function to facilitate rapid application site
- Online firmware upgrade
- Online update firmware version, adding new features at any time
3, calculations show some
IPC: IPC-610
This machine is configured to PentiumIV series, matching CPU / hard disk / memory / drive / floppy drive / mouse / keyboard, Advantech original machine,Service of the whole country.
![]() | Main Features
|
IPC-610H | Main Board: PCA-6006LV / CPU: PentiumIV 2.8G / Memory: 512MB SDRAM / Hard Drive: HDD 80GB |
Total length of Advantech CPU card PCA-6006LV![]() | Performance description:
|



PCI-1612A
4-port communications card RS-232/422/485PCI
PCI-1612 is a specification compatible with the PCI2.1/2.2 bus 4-port RS-232/422/485 PCI communication card that provides a transfer rate of up to 921.6Kbps. The PCI-1610 also uses 128-byte FIFO with a high-performance 16PCI954 UART chip, can greatly reduce the CPU load. These components work to make it more stable and reliable. Due to these features, PCI-1612 is very suitable for use in multi-tasking environment. 
- PCI bus specification 2.1 compliant
- Communication rate of up to 921.6Kbps
- 4-port RS-232/422/485
- I / O address automatically from the distribution of PCI plug-and-play function
- Optional over-voltage protection
- To improve system performance of the Interrupt Status Register
Suitable for enterprise-wide visualization and HMI solutions

Industrial Ethernet using breakthrough technology, amazing vector graphics, HMITECH vertical and horizontal integration and system-level technology solutions, HMIBuilder2.0 software will make you fresh and new. It has a user-friendly, easy to operate, powerful, easy to expand the structure and so on. It contains the following sub-modules: real-time processing module SCADA, data configuration module Data, a window configuration module Draw, Window Control Module View, alarm browser module AlarmViewer, statements module configuration ReportDesign, script configuration module ScriptDebugger. Several modules which together form a whole, to meet the diverse needs of users.
HMIBuilder man-machine interface (HMI) configuration software is based on distributed software bus technology. Powerful network. Network through a user-friendly configuration, easy to share the load of network nodes to support a wide range of network topology. Intuitive user interaction configuration configuration, high reliability, real-time monitoring and man-machine interface system HMITECH seamless integration, you will receive high-cost performance of the system-level solutions.
Distributed HMIBuilder configuration software is opening up a high-performance and highly scalable HMI configuration software, the network is not only powerful, but also with sophisticated graphics tools and superior performance of the real-time and historical databases, applications for agency design industry unparalleled power and flexibility. Support for distributed software HMIBuilder standard fieldbus communications, provides industrial automation equipment and the most standard connectivity.
Whether you are engineers or operators, end users or system integrators, OEM or VAR, HMITECH HMIBuilder distributed software will be required to provide you with groundbreaking features, the project implementation and operation of the production process monitoring to ensure that you are able to achieve performance breakthrough to improve assessment.
Powerful, cutting-edge technology, industry standards, efficient use
HMIBuilder industrial configuration software is distributed, has been very good in power remote oilfield environmental protection, equipment, factory automation and other fields. HMIBuilder 2.0 generic version of configuration software with many features and performance, including:
- Powerful network function
- Distributed management, configuration and monitoring, support for stand-alone, single-network, network topology, such as dual-network.
- Network architecture, the nodes can be classified according to function, the realization of distributed architecture, a number of background and workstations, to achieve load sharing.
- According to IP division to monitor the realization of multi-storey structure.
- Software Bus technology supported by HMIBuilder SCADA module, through the Industrial Ethernet to connect the physical nodes to form a soft bus.
- Complete database configuration
- Real-time database, real-time data retrieval faster. Hash algorithm used in real-time database, a large amount of data Quick Search! Points to support the smooth implementation of projects. Clear real-time configuration data structure. Station parameters for equipment to equipment based on the definition of the overall parameters of different data types. Script definition of local parameters of the calculation does not account for points configuration software.
- The history of the database configuration, data sets HMIBuilder database is saved to disk, savegroup database capacity of 4G.
Save the script command support, you can respond to a variety of scheduling methods. Export to ODBC database support, support for statements such as the historical curve.
- Expansion of flexible configuration
- TCL (Tool Command Language) language, syntax is simple, easy to master, HMIBuilder expansion provides a wealth of TCL command
- Expansion of a wide range of standard communication, the full support of OPC2.0, support of DDE, the standard supports a variety of fieldbus communications and the Statute
- Powerful graphics metafunction Photo
- Bright, non-resolution adaptive function View window to meet the authenticity, clarity and attention requirements
- Full vector graphics, pixel-rich, fully consistent with the Windows graphics habits, so that software engineers, designers and non-procedure to quickly customize new applications;
- Graphics library to provide a large number of yuan into a Photo. Multiple sub-pixel group can be configured to view the sub-group element attributes can be modified sub-group element property; Photo million warehousing functions into a pre-built frightening comprehensive library of graphic symbols;
- Support third-party library of graphic symbols, such as the Symbol Factory Vision2.0 compatible with 4000 kinds of library automation category of vector million, and the script can be integrated to facilitate the completion of the second modified set; through reusability and standardization of the volume of savings in the project;
- Easy-to-use animation graphic element, select the configuration element attributes, configuration results immediately displayed. That is established can see!
- Safety and security configuration
- Alarm handling mechanism to improve and provide automatic alarm display, rapid voice alarm configuration, support for ODBC alarm automatically save and save to provide alarm and alarm browser browser graphic elements to support the distributed disk server alarm
- User rights management, the realization of the project configuration encryption protection, the protection of intellectual property rights configuration works.
- High compatibility. Versions, customs, embedded, network-one. Systems to support Windwos 98 / 2000 / xp / xpe / vista.
HMIBuilder the HMITECH configuration software enables engineers to not only build an attractive, intuitive, safe, reliable and maintenance of HMI, SCADA and MES applications, but also with higher productivity and creativity, at the same time can reduce application development costs.

Industry to control the scene of the landscaping equipment graphical interface

Industry to control the scene of the landscaping equipment graphical interface